            Ring Main 
            Unit  
            : 
              
              
            RING MAIN UNIT : 
            TYPE GR1 | 
            
             ¡¡  | 
           
         
        
       
      
        
        
          
            | ¡¡ 
              
            
              
                | 
                 
            
                  
              Key Features 
                  
            SF6 gas insulation and current interruption 
            NO FIRE HAZARD  
                  
            Maintenance free and sealed for life contact 
            system  
                  
            Outdoor installation  
                  
            Robust construction  
                  
            Tee-off circuit breaker with integral 
            protection system  
                  
            Low cost cable termination  
                  
            Fully extensible options  
                  
            Internal arc-fault proven  
                  
            Motorized  
                 
                
            
                  
              SPECIFICATION 
                  - 
                  
Rated Voltage : 12kV  
                  - 
                  
Impulse Withstand 
                  Voltage : 95kVp  
                  - 
                  
Frequency : 50Hz  
                  - 
                  
Normal Current, Ring 
                  Switch : 630A  
                  - 
                  
CB : 630A  
                  - 
                  
Short-circuit Breaking 
                  Current, CB : 20kA  
                  - 
                  
Short-time Withstand 
                  Current : 20kA, 3 Seconds  
                  - 
                  
Short-circuit Making 
                  Current, Ring Switch : 50kAp  
                  - 
                  
CB : 50kAp  
                  - 
                  
Earthing Switch : 50kAp  
                 
                
            
                  
              COMPLIANCE WITH 
                  - 
                  
IEC56:1987, BS5311:1988  
                  Tee-off Circuit Breaker  
                  - 
                  
IEC3+6:1983, BS5463:1977  
                  Ring Switch  
                  - 
                  
IEC129:1984, BS5253:1975  
                  Earthing Switch  
                  - 
                  
Temperature Range  
                  +40¡É to -25¡É  
                 
                
            ¡¡  | 
               
               
             | 
           
         
        
       
      
                 
      
        
¡¡  | 
    
    
      
      
        
          
                
        
          
          Copyright(c)since 2003 Reliance Corp. 
          All right reserved 
          1304, Kumkwang Benesta,1149-2, Jung-Dong, Wonmi-Gu, 
          Bucheon-city, Gyeonggi-do 420-020, KOREA | 
         
        | 
         
       
       |