Cables :
  Control cables

¡¡


Scope of Application

Control cables are used in the site of control cuit, monitoring circuit and protective lines that have A.C rated voltage of 600/1000V and below. A connecting lines between various electric appliances, they have common type cable, flame retardant type cable, fire resistant type cable, oxygen barrier type cable, high temperature resistant type cable, freezing resistant type cable, halogen free type cable, low smoke and low halogen type cable, screened type cable, armoring type cable, moving type cable, fixed type cable, water proof type cable, corrosiom proof lead sheathing type cable and k3 kind nuclear class cables etc. with fluorocarbon, polyvinyl chloride, cross-links polyethylene, thermoplastics elastomer, fire resistant mica tape and nylon combined insulations respectively.

Product Standard : GB9330 and enterprise standard

Rated voltage : 600/1000-450/750-300/500-150/250V

Admissible longterm operation temperature of conductors : 200-105-90-80-70¡É

Series of cross sections : 0.5-0.75-1-1.5-2.5-4-6-10§±

Series of cores number : 1-2-3-4-5-6-7-8-10-12-14-16-19-24-30-37-44-48-52-61 core

Cable specifications : Core number x cross section

lay-up temperature of polyvinyl chloride insulated or sheathed cable is not less than 0¡É

Recommended permissive bending radius :

All plastic cables are not less than 6 times of cable outer diameter and the others are not less than 12 times

Type, name, main applicable site of cables
¡¡

Type Name Main application site
KVV Copper cores, polyvinyl chloride insulated and sheathed control cables To lay inside room, in cable pit, cable channel of fixed site
KVVP Copper cores, polyvinyl chloride insulated and sheathed and braiding screen control cables To lay inside room, in cable pit and cable channel of fixed site etc. The cable screening is required
KVVP2 Copper cores, polyvinyl chloride insulated and sheathed copper tape screening control cables To lat inside room. in cable pit and cable channel of fixed site etc. The cable screening is required
KVVP3 Copper cores, polyvinyl chloride insulated and sheathed aluminum-plastic tape screening control cables As above
KVV22 Copper cores, polyvinyl chloride insulated and sheathed and steel tape armoring control cables To lay inside room, in cable pit cable channel and direct burial of fixed site etc, that cable can be withstood by outer heavy mechanical force.
KVV32 Copper cores, polyvinyl chloride insulated and sheathed, fine steel wires armoring control cables To lay inside room, in cable pit, cable channel and well that can be withstood by heavy mechanical pulling force
KVV22P Copper cores, polyvinyl chloride insulated and sheathed, braiding screening and steel tape armoring control cables As above
KVV22P2 Copper cores, polyvinyl chloride insulated and sheathed, copper tape cleaned, steel tape armoring control cables As above
KVV22P3 Copper cores, polyvinyl chloride insulated and sheathed, aluminum-plastics screened, steel tape armoring control cables As above
KVV32P Copper cores, polyvinyl chloride insulated and sheathed, braiding screened and fine steel wires armoring control cables To lay inside room, in cable pit, cable channel and well of fixed site etc. that cable can be withstood by heavy mechanical pulling force.
KVV32P2 Copper cores, polyvinyl chloride insulated and sheathed, copper tape screened and fines steel wires armoring control cables As above
KVV32P3 Copper cores, polyvinyl chloride insulated and sheathed, aluminum plastics tape screened and fine steel wires armoring control cables As above
KVVR Copper cores, polyvinyl chloride insulated and sheathed flexible control cables The cables is moved about inside room. Flexibility of cable is required
KVVRP Copper cores, polyvinyl chloride insulated and sheathed, braiding screened flexible control cables The cable is moved about inside room, Flexibility of cable is required
KYV Copper cores, polyethylene insulated. polyvinyl chloride sheathed control cables To lay inside room. in cable pit and cable channel of fixed site etc.
KYVP Copper cores, polyethylene insulated, polyvinyl chloride sheathed, braiding screened control cables To lay inside room. in cable pit and cable channel of fixed site etc. The cable screening is required
KYVP2 Copper cores, polyethylene insulated, polyvinyl chloride sheathed, copper tape screened control cables As above
KYVP3 Copper core, polyethylene insulated polyvinyl chloride sheathed and aluminum-plastics screened control cables As above
KYV22 Copper core, polyethylene insulated, polyvinyl chloride sheathed and steel tape armoring control cables To lay inside room, in cable pit, cable channel and direct burial of fixed site etc. that can be withstood by heavy mechanical pulling force.
KYV32 Copper core, polyethylene insulated, polyvinyl chloride sheathed and fine steel wires armoring control cables To lay inside room, in cable pit, cable channel and well of fixed site etc, that cable can be withstood by heavy mechanical pulling force
KYV32P Copper core, polyethylene insulated, polyvinyl chloride sheathed, braiding screened and fine steel wires armoring control cables To lay inside room, in cable pit, cable channel and direct burial etc. of fixed site that cable be withstood by heavy mechanical pulling force
KYV32P2 Copper core, polyethylene insulated, polyvinyl chloride sheathed, copper tape screened and fine steel wires armoring control cables As above
KYV32P3 Copper core, polyethylene insulated, polyvinyl chloride sheathed, aluminum-plastics screened and fine steel sires armoring control cables As above
KYVR Copper core, polyethylene insulated and polyvinyl chloride sheathed, flexible control cables The cable is moves about inside room. Flexibility of cable is required
KYVRP Copper core, polyethylene insulated, polyvinyl chloride sheathed and braiding screened control cables The cable is moved about inside room. Flexibility and screening of cable is required
KYJV Copper core, cross linked polyethylene insulated and polyvinyl chloride sheathed control cables To lay inside room, in cable pit and cable channel and direct burial etc. of fixed side that cable can be withstood by heavy mechanical pulling force cable screening is required
KYJVP Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed beading screened control cables To lay inside room, in cable channel of fixed site, Cable screening is required
KYJVP2 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed and copper tape screened control cables As above
KYJVP3 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed aluminum-plastics tape screened control cables As above
KYJV22 Copper core, cross linked polyethylene insulated. polyvinyl chloride sheathed and steel tape armoring control cables To lay inside room, in cable pit, cable channel and direct burial of fixed side etc. that cable can be withstood by outer heavy mechanical force.
KYJV32 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed fine steel wires armoring control cables To lay inside room, in cable pit, cable channel, direct burial and well of fixed site etc, that cable can be withstood by heavy mechanical pulling force
KYJV22P Copper core cross linked polyethylene insulated, polyvinyl chloride sheathed braiding screened and steel and steel tape armoring control cables To lay inside room. in cable pit cable channel and direct burial of fixed site etc, that cable can be withstood by outer heavy mechanical force the cable screening is required
KYJV22P2 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed, copper tape screened and steel tape armoring control cables As above
KYJV22P3 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed, aluminum-plastics tape screened and steel tape armoring control cables As above
KYJV32P Copper core, cross linked polyethylene insulated polyvinyl chloride sheathed, braiding screened and fine steel wires armoring control cables To lay inside room, in cable pit, cable channel and well of fixed site etc, that cable can be withstood by heavy mechanical pulling force. The cable screening is required
KYJV32P2 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed, copper tape screened and fine steel wires armoring control cables As above
KYJV22P3 Copper core, cross linked polyethylene insulated, polyvinyl chloride sheathed, aluminum-plastics tape screened and fine steel wires armoring control cables As above

Flame retardant and fire resistance cables types and others
  • Flame retardant cable type : in the item 9 the type prefix "ZRA(B,C)--" i.e. falme retardant type A,B,C i.e. flame retardant properties class
    For example :
    ZRC-KVV Copper core, polyvinyl chloride insulated and sheathed class C flame retardant control cables
    ZRA-KVV Copper core, polyvinyl chloride insulated and sheathed class A flame
    retardant control cables
  • Fire resistance type : in the item 9 the type prefix "NH A (B)-", i.e. fire resistance type A.B, are fire resistance properties class.
    For example :
    NHB-KVV Copper core, polyvinyl chloride insulated and sheathed class B fire resistance control cables
    NHA-KVV Copper core, polyvinyl chloride insulated and sheathed firr resistance control cables class A
  • Fluoro-plastic insulated code-F
  • Nuclear class control cable code-HK
  • Halogen free flame retardant code-W
  • Nylon code-N
  • Lead code-Q

    

¡¡

Copyright(c)since 2003 Reliance Corp. All right reserved